负荷区
- 与 负荷区 相关的网络例句 [注:此内容来源于网络,仅供参考]
-
Set up the air cooling zone to increase the supercooling of steam and air mixture.
布置空气冷却区,增大排出的蒸汽-空气混合物的过冷度,以减小工质损失,并降低抽气器的负荷
-
Set within the rear half of the load area is an underfloor storage space which is a useful 250 mm deep and adds 53 litres to the Accord Tourer's overall load space.
在货物区的后半部是一个地板下设置的存储空间,它是一个有用的250毫米深,并增加了53升的雅阁旅行车的整体负荷空间。
-
Based on the principles of stepped firing in recirculation zones, several new type straightjet and revolving-pour burners are designed and manufactured which used for different power boilers and industral furnaces with combustion of pulverized coal, poor-gas or fuel-oil. The burners are tested and improved in practice and good results are finally achieced in variant degrees including strenthening flame stability, adapting to boiler capacities and rank of coal, raising combustion and heat transfer efficiency, and lowering the temperature of weste gas at the boiler tail.
应用回流区分级着火原理,设计和制造了几种不同结构型式的直流、旋流新型燃烧器,用于燃煤粉、煤气、油雾的不同类型的锅炉和工业炉,在实践中进行试验和改进,最终都在不同程度上取得了强化稳定燃烧、适应负荷和燃料品质变化、提高燃烧和传热效率、降低炉尾烟温的好效果。
-
Additionally, the air cooling zone should be set up so as to cool the steam and air mixture. Thus, the steam and air mixture supercooling can be enlarged, the working medium loss reduced and the burden of air ejector taken away.
另外,应该设置空气冷却区,使蒸汽-空气混合物得到冷却,以增大排出的蒸汽-空气混合物的过冷度,减少工质损失,并降低抽气器的负荷。
-
The cold-flow field in the gasifier chamber is studied.
本文对水煤浆气化炉喷嘴进行了简化处理,在此基础上,对气化室内的冷态流动过程进行了研究,发现:整个气化室都处于流动的回流区长度范围以内;水煤浆气化炉中,由于操作压力很高,气相密度很大,所以即使对于d〓=150μm的较大煤颗粒,其对流体的跟随特性也很好,没有发生流动特性突跃的现象;两相的最大回流速度、回流强度,颗粒相的浓度分布,以及气化室内的静压力损失等,均与气化炉的负荷、水煤浆浓度、煤粒直径、O〓在喷嘴两个流道中的分配比例。
-
The nozzle of the gasifier is simplified. The cold-flow field in the gasifier chamber is studied. The research shows that the chamber has recirculation along the whole length. The particles in the chamber perform a very good flowing characteristics even for the large particles of dp=150μm, and no abrupt change is observed. This is due to the operational pressure is high and the density of the gas is large there. The maximal reflux velocity of both phases, the reflux intensity, the concentrational distribution of particles, and the static pressure loss in the chamber are all related to following factors: the load of gasifier, the concentration of coal-water slurry, the diameter of the coal particle, the distribution ratio of oxygen in the two channels of the nozzle, and the angle of jet in nozzle.
本文对水煤浆气化炉喷嘴进行了简化处理,在此基础上,对气化室内的冷态流动过程进行了研究,发现:整个气化室都处于流动的回流区长度范围以内;水煤浆气化炉中,由于操作压力很高,气相密度很大,所以即使对于dp=150μm的较大煤颗粒,其对流体的跟随特性也很好,没有发生流动特性突跃的现象;两相的最大回流速度、回流强度,颗粒相的浓度分布,以及气化室内的静压力损失等,均与气化炉的负荷、水煤浆浓度、煤粒直径、O2在喷嘴两个流道中的分配比例、以及喷嘴的射流角等参数有关。
-
It makes generating unit connecting with power grid difficult and causes phase modulation condition shifting to power generation operation and turbine in load rejection for stopping unit to produce non-stability operation area.
S特性使机组在难以正常并网并造成由调相工况转发电运行以及水轮机工况的甩负荷停机过程中产生不稳定运行区。
-
Room cooling loads increase along with buliding area increasing, and ventilation efficiency minishes along with buliding area increasing.
2工作区冷负荷随建筑面积的增大而增大,且房间通风效率随房间高度的增加而降低。
-
This design is the Guangzhou lan west 100 markets summer the central air-conditioning system design, the primary mission completes one, two, three, four buildings load computation; Air-conditioning system plan efficient analysis and water unit's shaping; The air-conditioning system freezing stands design; Four buildings shopping area air conditioning unit's shaping, wind system and aqueous system design; Four buildings work area air blower plate tube system design; And has drawn up four winds tubes floor-plan, the wind side chart, the engine room floor-plan, the aqueous system axis side chart.
本次设计课题是广州市蘭西一百商场夏季中央空调系统设计,主要任务是完成一、二、三、四楼的冷负荷计算;空调系统方案的经济性分析和制冷机组的选型;空调系统冷冻站的设计;四楼购物区空调机组的选型,风系统和水系统的设计;四楼办公区风机盘管系统的设计;并绘制了四层风管平面布置图、风管轴侧图、机房平面布置图,水系统轴侧图。
-
This design is the Guangzhou lan west 100 markets summer the central air-conditioning system design, the primary mission completes one, two, three, four buildings load computation; Air-conditioning system plan efficient analysis and water unit's shaping; The air-conditioning system freezing stands design; Four buildings shopping area air conditioning unit's shaping, wind system and aqueous system design; Four buildings work area air blower plate tube system design; And has drawn up four winds tubes floor-plan, the wind side chart, the engine room floor-plan, the aqueous system axis side chart.
该下载资料由本站会员上传,如果侵犯了您的权力,请通知我们,将立即删除!摘要本次设计课题是广州市蘭西一百商场夏季中央空调系统设计,主要任务是完成一、二、三、四楼的冷负荷计算;空调系统方案的经济性分析和制冷机组的选型;空调系统冷冻站的设计;四楼购物区空调机组的选型,风系统和水系统的设计;四楼办公区风机盘管系统的设计;并绘制了四层风管平面布置图、风管轴侧图、机房平面布置图,水系统轴侧图。
- 推荐网络例句
-
But we don't care about Battlegrounds.
但我们并不在乎沙场中的显露。
-
Ah! don't mention it, the butcher's shop is a horror.
啊!不用提了。提到肉,真是糟透了。
-
Tristan, I have nowhere to send this letter and no reason to believe you wish to receive it.
Tristan ,我不知道把这信寄到哪里,也不知道你是否想收到它。