有支架的
- 与 有支架的 相关的网络例句 [注:此内容来源于网络,仅供参考]
-
6 cases of urethostenosis, 2 cases of urotithiasis and 1 case of urethral valves were cured one time. They were followed up from 10 months to 6 years and no dysuria occurred. 2 cases of external plank shedding after ureteropelvioplasty were treated with a placement of internal plank through the renal fistulization. The placement and evulsion of internal plank were carried out one time in 8 cases of ureteric calculi (the length of one calculi was as long as 4cm) and 12 cases of ureteropalsty. In 5 cases of upper remotion of internal plank, 4 cases were pulled out successfully and one failed to draw out. The effect is satisfactory to treat urological diseases by means of ureteroscopy in children.
结果 6例尿道狭窄、2例尿道结石、1例尿道瓣膜均一次性治愈,随访10个月~6年,无排尿异常。2例肾盂输尿管成形术后外支架管脱落经肾造瘘口放置内支架;8例输尿管结石(1例石街长约4cm)、12例输尿管成形术后内支架置入和/或拔出均一次完成。5例内支架上移中4例顺利拔出,1例失败、结论输尿管镜对小儿尿路系统大部分疾病的处理有满意效果。
-
RESULTS AND CONCLUSION: The seeded cells had chondrogenesis in scaffolds under certain conditions.
结果与结论:种子细胞在三维支架中特定条件下有成软骨效应,骨髓间充质干细胞在含20%透明质酸的胶原/透明质酸支架扩增少于3代有成软骨效应,软骨细胞传代数更高仍然有成软骨效应,但脂肪源性成熟基质细胞成软骨效应能力较弱。
-
Methods: The coated metallic stents were introduced by direct observation of endoscopy for 30 patients with cancerous esophagotracheal fistula. The all 30 cases of the patients were associated with pulmonary infection,dystrophia and choke before the operation. The success rate of the implantation,complication rate and curative effect were observed after the operation. Results: The first success rate of the patients was 100%. All patients could take food after the operation and the pulmonary infection was also controlled apparently. The median survive time was 10 months.
在内镜直视下置入国产金属带膜支架,观察支架置入成功率、操作相关并发症、支架疗效和并发症等指标。30例癌性食管气管瘘患者,术前伴明显的肺部感染和严重营养不良及进食呛咳等症状,结果:30例患者支架置入术操作一次成功率为100%,支架置入术后患者进食困难均有改善,肺部感染得到明显控制,随访平均生存时间10月(2~16月)。
-
However, tracheal stent implantation is different from esophageal stent implantation. As patients with airway obstruction are always complicated by dyspnea and hypoxemia, even respiratory failure, which increases risk and difficulty of stent implantation. During tracheal stent implantation, the bronchofibroscope or stent entering the stenosis site may lead to complete tracheal obstruction-induced asphyxia. Corrosion of metal wire of stent to airway mucosa and vessels may result in hemorrhea, leading to postoperative hemoptysis. Stent dislocation is mainly caused by inappropriate selection of stent, inappropriate implantation position or severe cough. Carcinoma tissue growing along stent lumens can induce re-obstruction in stent, resulting in atelectasis relapse.
气管及食管支架置入均属有创性治疗,但气管支架置入不同于食管支架置入,气管阻塞患者均有不同程度的呼吸困难和低氧血症,甚至发生呼吸衰竭,加大了支架置入的风险和难度;气管支架置入者,当纤支镜或支架进入狭窄部位时可造成气管的完全阻塞引起窒息;支架金属丝对气管黏膜血管的侵蚀可引起大出血,导致术后咯血;支架移位主要由支架选择不当、置入不到位或剧烈咳嗽引起;癌组织沿支架网眼长入造成支架内再阻塞可引起肺不张复发。
-
The base is equipped with an X-axis workbench, a Y-axis workbench and a microscope, a bonding head is arranged above the workbench, a liftable support is arranged on the base, the microscope is mounted on the liftable support and provided with a Z-axis stepping motor, and an automatic magnification regulating mechanism is arranged on the microscope.
在底座上设置有X轴工作台、Y轴工作台和显微镜,在工作台的上方设置有键合头,在底座上还设置有可升降支架,显微镜安装在可升降支架上并且在显微镜上设置有Z轴步进电机,显微镜上安装有放大倍数自动调节机构。
-
Trans-Blot Cells and Systems 170-3825 Trans-Blot Cell With Wire Electrodes and PowerPac HC Power Supply, 100120/220240 V, includes 2 gel holder cassettes, buffer tank, lid with power cables, 4 fiber pads, 1 pack precut blot absorbent filter paper (15 x 20 cm), power supply, power cord, instructions 170-3850 Trans-Blot System With Plate Electrodes and PowerPac HC Power Supply, 100120/220240 V 170-3853 Trans-Blot System With Plate Electrodes, Super Cooling Coil, and PowerPac HC Power Supply, 100120/220240 V, includes 2 gel holder cassettes, buffer tank, lid with power cables, 4 fiber pads, 1 pack precut blot absorbent filter paper (15 x 20 cm), power supply, power cord, instructions 170-3910 Trans-Blot Cell With Wire Electrodes, includes 2 gel holder cassettes, buffer tank, lid with power cables, 4 fiber pads, 1 pack precut blot absorbent filter paper (15 x 20 cm) 170-3939 Trans-Blot Cell With Plate Electrodes and Super Cooling Coil, includes 2 gel holder cassettes, buffer tank, lid with power cables, 4 fiber pads, 1 pack precut blot absorbent filter paper (15 x 20 cm) 170-3946 Trans-Blot Cell With Plate Electrodes, includes 2 gel holder cassettes, buffer tank, lid with power cables, 4 fiber pads, 1 pack precut blot absorbent filter paper (15 x 20 cm) Trans-Blot Cell Accessories 170-3912 Super Cooling Coil, required for all high-intensity transfers 170-3913 Gel Holder Cassette, includes 2 fiber pads 170-3914 Fiber Pads, 15.5 x 20.5 cm, 6 170-3920 Trans-Blot Standard Wire Electrode Card, cathode 170-3921 Trans-Blot Standard Wire Electrode Card, anode 170-3922 Trans-Blot Cell Buffer Tank 170-3923 Trans-Blot Cell Lid With Power Cables 170-3943 Trans-Blot Platinum Anode Plate Electrode 170-3944 Trans-Blot Stainless-Steel Cathode Plate Electrode 170-3945 Trans-Blot Plate Electrode Pair, platinum anode and stainless-steel cathode 16 规格:说明: Trans-Blot Plus
电泳转印槽组件 1。缓冲液槽及带有电缆的盖 2。凝胶支架转印夹 3。纤维衬垫 4。电极丝 5。电极板 6。特级冷却芯 Trans-Blot 转印槽是功能灵活的转印设备,可理想地用于多种转印应用。Trans-Blot 转印槽特点包括:*能进行多胶转印,可容纳3 块PROTEAN I xi 凝胶、6块Criterion 凝胶、12块Mini-PROTEAN 3 或Ready Gel 预制胶*多组参数灵活可设,可调节的电压设置(从30 V 的过夜转印到200 V 的1 小时快速实验)*电极间距设置为8 cm 用于标准印迹杂交,或设置为4cm 用于高强度印迹杂交*可选择板式电极:涂有铂金的钛作为正极,不锈钢为负极,能提供高强度电场和比其它电极更高的电流密度。或选择较经济的铂金电极丝*通过特级冷却芯和水循环仪来调节温度―是天然酶(4°C)或高强度转印的理想选择,随着转印时间增加(多达24 小时),不会引起缓冲液耗竭(在高强度转印中必须使用冷却芯,也推荐用于所有板式电极的应用)*带铰链的凝胶支架转印夹能避免滑动,确保凝胶与印迹膜间的紧密接触;每个转印夹都有颜色标记以保证在转印槽中的正确定位 Trans-Blot 转印槽的锁闭凝胶支架转印夹系统。转印夹(1)支撑凝胶(2)印迹膜(3)两侧有纤维衬垫和滤纸(4)确保凝胶三明治内的完全接触。凝胶夹垂直插入缓冲液槽中(5)。
-
Erection parameters in the literature [9] nonlinear analysis method used to calculate some of the variables erection capacity limit, but no major erection of some other variables, such as the level of the top-Ligan excess of the limit load length the impact of, and the top model Ligan more displacement constraints, and the actual situation of access to a certain extent; literature [7] space will be just as Falsework framework erection of the main parameters of the critical load, and The literature [10] scaffold for the ultimate strength estimation method for calculating the results of the amendment.
在搭设参数方面,文献[9]采用非线性分析方法,计算了部分搭设变量下的极限承载力,但是没有分析另外一些主要搭设变量如立杆超出顶层水平杆长度对极限承载力的影响,而且计算模型的顶部立杆位移约束较多,和实际情况有一定的出入;文献[7]将模板支架视为空间刚框架,分析了主要搭设参数下的临界荷载,并采用文献[10]提出的用于外脚手架极限承载力的估算方法对计算结果进行了修正。
-
With rapid development of express way and city traffic and the type for city bridges, interchanges and viaducts such as continuous curved girder bridges are widely used. To get beautiful linetype, the top structure of bridge is required to apply cast-in-place technology. Therefore scaffold construction technology for beams are greatly applied.
随着桥梁结构型式的发展,以及近年来高速公路及城市交通的迅猛发展,变宽桥、弯桥等复杂的预应力混凝土结构得到了广泛的应用,因线型限制,桥梁上部结构一般采用现浇,这样有支架现浇技术得到了广泛的应用,同时应用中的技术、安全问题也日益突现出来。
-
RESULTS: Expression of iNOS proteins was seen on day 1 following the control stent implanting, developed on day 3, peaked on day 10 and lasted till day 28. iNOS expressions at all time points in diallyl trisulfide coated stent group were higher than those in control stent group. Compared with normal blood vessel tissue, the NO production after stenting decreased on day 1, increased on day 3, maximized on day 10, went down to its pre????stenting level on day 28. At all time points, NO levels in allitridi????stented sites were higher than those in control????
结果: 对照支架组术后1 d血管壁中有少量iNOS蛋白表达,3 d表达增加,10 d达高峰,28 d时仍有表达,二烯丙基三硫化物涂层支架组iNOS蛋白在各时间点的表达量均高于对照支架组;对照支架组术后1 d时NO生成量低于正常组织,3 d时NO水平升高,10 d时最高,28 d时降至基线水平,二烯丙基三硫化物涂层支架组各时间点的NO水平明显高于对照支架组。
-
Results: expression of inos proteins was seen on day 1 following the control stent implanting, developed on day 3, peaked on day 10 and lasted till day 28. inos expressions at all time points in diallyl trisulfide coated stent group were higher than those in control stent group. compared with normal blood vessel tissue, the no production after stenting decreased on day 1, increased on day 3, maximized on day 10, went down to its pre stenting level on day 28. at all time points, no levels in allitridi stented sites were higher than those in control stented sites.
结果: 对照支架组术后1 d血管壁中有少量inos蛋白表达,3 d表达增加,10 d达高峰,28 d时仍有表达,二烯丙基三硫化物涂层支架组inos蛋白在各时间点的表达量均高于对照支架组;对照支架组术后1 d时no生成量低于正常组织,3 d时no水平升高,10 d时最高,28 d时降至基线水平,二烯丙基三硫化物涂层支架组各时间点的no水平明显高于对照支架组。
- 推荐网络例句
-
In the United States, chronic alcoholism and hepatitis C are the most common ones.
在美国,慢性酒精中毒,肝炎是最常见的。
-
If you have any questions, you can contact me anytime.
如果有任何问题,你可以随时联系我。
-
Very pretty, but the airport looks more fascinating The other party wisecracked.
很漂亮,不过停机坪更迷人。那人俏皮地答道。