扫描范围
- 与 扫描范围 相关的网络例句 [注:此内容来源于网络,仅供参考]
-
The cycling life of Ni 〓 was measured with powder microelectrode by cyclic voltammetry for the first time. Results show that the depth of charge is up to 75%, and the depth of discharge almost reached to 100% when the scanning range is controlled within 0~ 0.6V vs.
对Ni〓粉末微电极的测试表明,当控制三角波扫描范围0~0.6V、扫描速度20mV/s时,每次循环电极的充电率可达到75%,而放电率接近100%,完成一个周期仅需要1分钟,因此极大地缩短了测试时间。
-
The system has a scan volume of 8 x 2 x 2 metres and is able to inspect parts which have a complex, dual curvature geometry, by virtue of the fact that the motion of the squirters on each side of the part are totally independent - ie they are not linked by a bridge or any other constraining structure.
系统的扫描范围是8*2*2m,可检测复杂双曲面零件,该功能的实现主要是由于零件两边的喷嘴能够完全独立地运动-例如,他们不与桥连接或任何其他的阻碍结构连接。
-
The expressions of the number of cycles in one photocurrent burst from the scattering light at different positions were shown.
对激光扫描测速技术中影响扫描频率提高的因素以及影响扫描范围、空间分辨率、空间分辨点数的因素做了分析和讨论。
-
Light engine scanning is in the way of spurring reflects to circle with the machine unit. The rule is easy, sweep range greatly, yet the problem is that the machine system is the bad accuracy and the stability is harder domination and so on.
光机扫描是用机械装置驱动反射系统旋转以实现激光光束的扫描,其原理简单,扫描范围大,但机械系统存在机构精度差、稳定性较难控制等不足。
-
Plain scan and enhanced scan were performed in these patients with Siemens 64-slice spiral CT with the following parameters: 1.0-mm section thickness,0.6-mm collimation,pitch of 1, voltage of 120Kv and tube current of 100mAs, The scanning range is from the thoracic inlet to posterior costophrenic angle; A 80-100ml dose of nonionic iodinated contrast material is injected intravenously at approximately 4-5 ml/sec.
扫描采用Siemens 64层螺旋CT;扫描参数选择层厚1 mm,准直0.6mm,螺距1,管电压120 kV,电流100 mAs;扫描范围从胸廓上口至后肋膈角;强化时对比剂为非离子型对比剂(碘海醇,350 mg I/ml),注射流率4~5 ml/s,对比剂总量80~100 ml;采用人工智能触发扫描技术,触发点选择肺动脉主干横断层面,阈值为100 HU,触发扫描延迟时间为6 s。
-
Methods:①Make clinical scale of the magnitude of the tongue and the palate to the group of the OSAHS and the normal control②Successive scanning of the upper airway at the states of the normal inspiration and under the Müller action on both normal controls and the OSAHS patients with multi-slice spiral computed tomography. The scope of scanning was from the roof of nasopharynx to the level of hypohyal, bonding multiplate volume reconstruction,using the image workstation to survey the cross section area, sagittal diameter, coronal diameter on the soft tissue thickness in the lateral pharyngealwall and posterior wall of the pharynx, and the postzone of soft palate, uvula palatine ,tongue and epiglottis.
采用高分辨率多排CT(multi-slice spiral computed tomography,MSCT)对正常人和OSAHS患者的上呼吸道分别在平静吸气状态下以及Müller动作下进行连续扫描,扫描范围从鼻咽顶部至舌骨下缘,图象进行三维重建,应用图像工作站测量正常人和OSAHS患者的软腭后区(retropalatal region,RP)、悬雍垂后区(uvula region,UV)、舌后区(retroglossal region,RG)和会厌后区(epiglottal region,EPG)气道横截面积(cross section area,CSA)、矢状径、冠状径、咽侧壁和咽后壁软组织厚度以及舌体大小(包括舌体长度、舌体最宽处的宽度、中纵切面面积,舌背高度)。
-
Craniocaudal view and mediolateral oblique were conducted for each patient.If necessary,mediolateral view or spot view was operated. All cases take plain scanner and contrast-enchanced scanner with use of a helical CT (Somatom AR.SP).For a patient,a field view was chosen that field depict the whole breast,as well as the ipsilateral axillary and internal mammary chains.
SP螺旋CT机进行平扫和增强扫描,扫描范围从腋窝顶部至乳房下界。23例全部采用增强扫描,分别在注射造影剂100ml后30s、60s、90s时进行动脉相、静脉相、延迟相CT扫描,病人采用俯卧位,上胸及腹部垫高,使乳房自然下垂,双臂交叉放在头上。
-
Spondylolysis were showed in sagittal images. Conclusion: The scan range were increased for the fourth lumbar to first sacroiliac interverteral disc and contained vertebral arch for conventional intervertebral disc. The spiral scanning were performed for lumbar spondyloschisis and with MPR along the direction of vertebral arch. The method is simple and useful for the patients suffered low-back pain.
对常规椎间盘扫描采用对L(下标 4~5)及L5~S1,椎间盘加大扫描范围,包括椎弓根层面的方法,对于轴位扫描发现或可疑峡部裂的患者再做相应椎体螺旋扫描,行平行于峡部的椎弓长轴多平面斜矢状面和矢状面重建,是腰腿痛病人CT检查的简单、实用的有效方法。
-
Methods Sixty-five patients with suspected nephrolithiasis and ureterolithiasis were collected. Followed by standard-dose helical CT scans with 2-mm-thick section, 120kv, 160mAs, low-dose scan was carried out with the tube current reduced to 60mAs. All other technical parameters and anatomic coverage remained constant.
收集65例临床拟诊肾及输尿管结石病例,每一病例在常规标准剂量(120KV, 160mAs)扫描后再行低剂量扫描,在低剂量扫描中,管电流下降到60mAs,其余参数及扫描范围均保持不变。
-
Pulse replicators can achieve both high dynamic range and long scan range, and satisfy single shot pulse contrast measurement.
脉冲复制器能够兼容高动态范围和大的时间扫描范围,实现单次信噪比测量的基本需求。
- 推荐网络例句
-
Breath, muscle contraction of the buttocks; arch body, as far as possible to hold his head, right leg straight towards the ceiling (peg-leg knee in order to avoid muscle tension).
呼气,收缩臀部肌肉;拱起身体,尽量抬起头来,右腿伸直朝向天花板(膝微屈,以避免肌肉紧张)。
-
The cost of moving grain food products was unchanged from May, but year over year are up 8%.
粮食产品的运输费用与5月份相比没有变化,但却比去年同期高8%。
-
However, to get a true quote, you will need to provide detailed personal and financial information.
然而,要让一个真正的引用,你需要提供详细的个人和财务信息。