英语人>网络例句>image storage space 相关的网络例句
image storage space相关的网络例句

查询词典 image storage space

与 image storage space 相关的网络例句 [注:此内容来源于网络,仅供参考]

Said invented door plank storable and superposable screen window has left and right storage boxes for holding the screen roller made up by rolling up screen, and comprises latch hook, coupling bar, upper and lower guideways, the left and right storage boxes are freely fixed on the upper and lower guideways, according to the requirements the left and right storage boxes can be slided, and can be formed into square frame together with upper and lower guideways, and the screen can be spread and laid on said square frame so as to form the invented door plank storable and superposable screen window.

通过把抑制由纱网卷绕收藏成纱网滚筒的左右的收藏箱及纱网的上下端边固持的纱网往面内外方向弯曲的挂钩装成相对于上、下导轨自由滑动,而且将在左右的收藏箱装成自由滑动的连动杆设置为和该上、下导轨的卡合孔自由卡合,将左右的收藏箱自由固定于上、下导轨,按照需要使左右的收藏箱滑动,和上、下导轨一起形成方形框,而且借着在自收藏于左右的收藏箱内的纱网滚筒拉开纱网下展开、铺设成该方形框,可形成门板状可收叠纱窗。

Based on a computing model of floor heating residences, indoor thermal environment and heat distribution under the effect of heat charge/discharge, operation control and solar radiation has been concluded. Concept and formula of equivalent heat supply has been put forward which indicate that actual heat supply will be equal to the sum of design heat supply and equivalent heat supply. Recommend coefficient has been given taken Dalian as an example. Computed according to the new method, design heat supply can be reduced to 37% in cloudy day and 43.3% in sunny day, energy saving effect is very obvious. In Tromb wall solar house, effect of concrete wall on indoor temperature swing and attenuation of temperature wave is very obvious. While the outdoor air-temperature swing exceeds 10℃, indoor air-temperature swing belows 3℃. In the experiment, maximal difference in temperature between inner surface and outer surface of the 300mm wall exceeded 10℃. Heat storage and collector efficiency varies adversely according to solar radiation. Factors such as thickness, material, absorptance of the wall and permeation of the glass cover all have big influence on heat storage and collector efficiency. There exsisted an optimal thickness of the wall, which can make the best of heat storage and collector efficiency. Most of the heat stored in conventional Trombe wall during the daytime has been lost to the outside at night without heat preservation. Heat preservation on the outside surface of the wall has effectively improved heat release performance of the wall at night, heat supply to the room has increased too.

通过建立的地板采暖系统动态热性能分析模型,得出了在蓄放热特性、运行方式和太阳辐射等因素耦合作用下的室内热环境及热量分配比例,提出了等效供热量的概念及计算公式,指出实际所需供热量应等于设计供热量加上等效供热量,并以大连为例,给出了等效供热量的修正系数,以新方法计算,阴天可减少设计供热量37%,晴天最大可以减少设计供热量43.3%,节能效果显著;集热蓄热墙式太阳房中,混凝土蓄热墙的室温均一化效果和对温度波的削减作用非常明显,当室外温度波动最大幅度超过10℃时,室温波幅不超过3℃,实验中300mm厚墙体内外表面温差超过10℃;墙体蓄热效率与集热效率随太阳辐射照度的变化呈相反的变化趋势;墙体厚度、材料、表面吸收率以及盖板透过率等因素对集热和蓄热效率均有较大的影响,存在一个最佳的墙体厚度值,使得墙体集热和蓄热综合性能最优;传统的蓄热墙夜间没有外保温,辐射散热损失很大,研究表明墙体外保温方式明显改善了蓄热墙夜间的散热性能,增加了向室内的供热量。

In this model, the skeletal storage coefficient was used for coupling, different storage coefficient were used for the calculation of storage change of aquifer and interbeds, the elastic and inelastic skeletal coefficients were used to account for the elastic and inelastic deformation, a one-dimensional diffusion equation was used for describing the delayed dissipation of unequilibrated heads within the interbeds, these make the model not only be able to simulate the elastic and inelastic deformation of soil, but also the delay phenomenon.

在该模型中,用夹层的骨架弹性储水系数进行地下水流模型和土体变形模型的耦合,用不同的弹性储水系数来计算夹层和含水层内的储水量变化,用夹层的骨架弹性储水系数和非弹性储水系数来体现夹层的弹性和非弹性变形,用扩散方程来描述滞后夹层内的水头分布,从而使模型能够很好地体现夹层的弹性和非弹性压缩,并能同时考虑夹层变形的滞后现象。

The result shows that the hydrogen storage properties increase remarkably after pure magnesium ball-milled with 10% TiFe(subscript 1-x)Cr (x=0, 0.3). Moreover, the chromium content also influences the hydrogen storage characteristics. Furthermore, the ball-milled composite of Mg+10%TiFe0.7Cr0.3 has the best hydrogen storage properties with hydrogenation capacity of 7.14% and dehydrogenation capacity of 6.91% at 613 K. In addition, the lower temperature of 493-573 K, the Cr-contained composite exhibits the best dehydrogenating kinetics.

研究结果表明:在纯Mg中添加质量分数为10%的TiFe(下标 1-x)Cr(x=0, 0.3)进行复合球磨,可以明显提高其吸放氢性能;在相同温度条件下,x=0.3的含铬复相合金具有最佳的吸放氢性能,其中在613 K下的吸氢容量为7.14%,放氢容量为6.91%;在493~573 K的较低温度下,含铬复相合金表现出更好的放氢动力学性能。

This paper introduced a few of methods of hydrogen storage,including compressed hydrogen, liquidized hydrogen,metal hydrides,carbon nanotubes,organic liquid hydrides storage,and commented their recent developments,and pointed out direction of hydrogen energy storage progress.

介绍了高压压缩储氢、深冷液化储氢、金属氢化物储氢、碳纳米管吸附储氢及有机液体氢化物储氢等几种储氢技术的发展现状,并指出储氢技术未来的发展方向。

Is specialized in mobile cold storage can be assembled design, material selection, installation, maintenance, consulting, services as one integrated company, storage products based on user type, quantity, time and investment in different economic To provide you with the design of high, medium and low-grade large, medium and small-scale and quick-freezing cold storage tunnels.

常州市春雪冷库设备有限公司是专业从事拼装可移动式冷库设计、选材、安装、维护、咨询、服务为一体的综合性公司,可根据用户贮藏产品的种类、数量、时间和经济投入的不同来为您设计按装高、中、低档的大、中、小型冷库及速冻隧道。

Quick-frozen quick-freezing plant with advanced production line, date processing capacity more than 20 tons, supporting three low-temperature storage, low temperature storage capacity of 1500 tons; preservation of products in production and processing capacity of 6000 tons, with sixhole more than 4.5 thousand tons preservation storage capacity.

速冻车间拥有先进的速冻生产线一条,日加工能力超过20吨,配套低温储存库3座,低温储存能力为1500吨;保鲜类产品年生产加工能力为6000吨,拥有6个恒温库洞,超过4500吨保鲜储藏能力。

The inevitable outcome of historical development is Storage Grid. Storage Grid renovates and manages storage resource in network.

存储网格将网络中的存储资源进行整合并统一进行管理,通过单一的管理路径即可掌控所有的存储资源。

The powder storage project of the Xilongchi Pumped Storage Power Station in Shanxi Province is a place that stores explosive powder and blasting equipment for the construction of the main bodies of Xilongchi Pumped Storage Power Station .

山西西龙池抽水蓄能电站炸药库是为主体工程施工集中存放炸药、爆破器材的地点,为寒武系灰岩,岩层近于水平,构造裂隙N-E向陡倾,在外力作用下卸荷开裂,溶蚀夹泥严重,开挖过程中时遇顶拱塌块、溶洞、断层,所以进行了锚喷支护。

And then, according to the above research, a portable instrument, based on PC-104 embedded technique, is designed for the inspection of the corrosions on oil storage tank floor. Some problems occurred during the testing, such as straightly walking、turning and installing of the instrument are solved. At last, the instrument is applied in the storage tank of ZhenHai chemical plant. It shows that the portable MFL instrument can detect 4mm diameter、0.5mm deep hole in 6mm thick plate and 8mm diameter、1.1mm deep hole in 12mm thick plate. The whole instrument is about 22kg heavy. The battery can keep on working for 6.5 hours. It is an efficient way for the testing of the corrosion on oil storage tank floor.

在上述实验研究的基础上,成功研制出一台基于PC104的便携式储罐底板腐蚀漏磁检测仪,解决了仪器使用过程中遇到的直线行走、转向和安装困难等关键问题,并在中国石化镇海炼化进行了应用,实验室和现场试验表明,该便携式储罐底板腐蚀漏磁检测仪能检出6mm厚钢板上φ4mm×0.5mm和12mm厚钢板上φ8mm×0.5mm的腐蚀坑,整体重量22kg,电池能连续工作6.5小时,很好的解决了储罐底板腐蚀的检测问题。

第26/500页 首页 < ... 22 23 24 25 26 27 28 29 30 ... > 尾页
相关中文对照歌词
In His Image
Mirror Image
Sage Comme Une Image
Space
Shattered Image
Outta Space Love
Image Of The Invisible
Space Cowboy
Imagine That
Space Age Whiz Kids
推荐网络例句

Listen,point and check your answers.

听,指出并且检查你的答案。

Warming needle is one of effective treatment methods for knee arthralgia aggravated by cold,and it is simple,safety,so it should be developed in clinical acupuncture and moxibustion extensively.

但以本院科针灸门诊在2005年1月—2006年6月期间共收治膝痛患者100余例,经过临床的诊断后,其中施以温针治疗的48例,疗效显著,报道如下。1临床资料本组病例48

Some known methods of remnant pump detection and automatic laser shut-down use communications, such as an OSC.

一些已知的残余泵浦检测和自动激光关断的方法利用诸如OSC的通信。