英语人>网络例句>heat-resistant 相关的网络例句
heat-resistant相关的网络例句

查询词典 heat-resistant

与 heat-resistant 相关的网络例句 [注:此内容来源于网络,仅供参考]

The purpose of this paper is to find the proper character of cooling water and the ways of it pass in and out the jet, which make sure that the anode of plasma ignition jet will not be ruined, to prolong the useful life of the pole, by using the numerical analyze in plasma ignition torch against heat transfer of anode and cooling-water against convection current heat transfer, and process the simulation calculation by using FLUENT soft.

本文通过对等离子体点火炬与阳极传热以及冷却水与对流湍流传热的数值分析,运用FLUENT软件进行模拟计算,找出满足使等离子点火器阳极不被烧蚀的冷却水的合理参数及冷却水进出水方式,来延长电极的使用寿命。

The modified model took into account not only the coupled heat transfer of conduction, convection and radiation, but also the heat convection between each zone caused by temperature difference and airflow.

该模型综合了墙体热传导、壁面对流热交换以及内部控制体之间的对流热交换过程。

By the analysis of heat transfer between air and wall in vertical direction and the mechanism of air flow in large space building, this paper provides a theoretical model that the air temperature in vertical direction can be divided into three zones: temperature-constant air-conditioning zone, main convection zone and top heat stagnation zone.

通过对大空间建筑室内垂直方向上空气与壁面换热和流动机理分析,提出了空气温度在垂直方向上划分为等温空调区、对流主区域、顶部热滞留区域三个区域,建立了对流主区域、顶部热滞留区域求解空气温度的数学模型,推导得到了相应的分析解,提出了计算大空间建筑室内垂直温度分布简易模型。

To some extent, the nucleate boiling and the two-phase forced convective heat transfer through the liquid film always co-exist in the saturated nucleate boiling zone and two-phase forced convection zone. The liquid fill-ratio, input power and content of the non-condensable gas exert significant influence upon the start-up performance and the heat transfer performance of LHP.

并且在饱和核态沸腾区与两相强制对流区内,总是在某种程度上同时发生着核态沸腾区与两相强制对流液膜传热;充液量、输入功率及其不凝性气体的含量对回路热管的起动性能和传热性能部有很大的影响。

The convectional heat transfer coefficients were measured and analyzed at different Reynolds numbers and constant heat flux.

在定热流边界条件及不同Reynolds数下测量并分析了对流换热系数。

It appears that improvement of convective heat transfer is very important for enhancement of flux and heat efficiency.

结果表明,提高对流传热系数是提高膜蒸馏热效率和渗透通量的关键。

The temperature、heat flux and solidified shell thickness were calculated in two different slab. The influence of casting speed to heat transfer was also analysised, and the calculation method of inverse problem model was studied. The convergence behavior of model was discussed under different methods and parameters.

对实际生产中两个不同的铸坯模型的结晶器温度、热流和铸坯凝固状况进行计算,分析了拉坯速度对结晶器传热的影响,并对反问题模型的计算方法进行研究,讨论了不同反算方法及参数下的模型收敛行为。

Years later, Coover was working in a Tennessee chemical plant and realized the potential of the substance when they were testing the heat resistance of cyanoacrylates, recognizing that the adhesives required neither heat nor pressure to form a strong bond.

六年之后,哈里在田纳西州的一家化工厂工作,当他们测试氰基丙烯酸酯的耐热性时,意识到这种物质的潜能,认识到这种粘剂既不需要加热也不需要加压就能产生很强的粘性。

The ventilation system consists of a supply and exhaust air unit with a counterflow heat exchanger which provides 85% heat recovery.

通风 通风系统包括一个送风单元,一个排风单元,与一个可回收85%热能的逆流式换热器。

By the furnace body, the stainless steel crucible, electrically operated toward the multiple swinging material frame, stainless steel fast Leng Bao, the heating unit and control the warm cabinet to be composed automatically, may use the different resolver, carries on components quenching, the tempering heating, the isothermal quench to cool, the liquid thermochemical treatment and so on many kinds of crafts, the furnace body becomes by the section and the steel plate welding, the stove surface uses δ=14mm the board to make, the nitre salt furnace lining uses the ultra light quality high strength 0.6g/cm3 micro bead refractory brick, clamps the stratification aluminum silicate textile fiber, the furnace lining and the furnace shell fills the heat preservation inflation heat preservation powder, the entire structure for the standard energy conservation furnace lining, the nitre salt stove's heating element uses the thick diameter 0Cr25Al5 high temperature resistance wire to circle spiral-shaped according to the average temperature cloth silk law,Places in the furnace lining puts on the silk brick, puts the silk brick to use the front part to go up 20° against falls the silk brick, the resistance wire is not easy to drop out.

由炉体、不锈钢坩锅、电动往复式摆动料架、不锈钢速冷包、电热元件和自动控温柜组成,可以使用不同溶剂,进行零件淬火、回火加热、等温淬火冷却,液体化学热处理等多种工艺,炉体由型钢和钢板焊接而成,炉面采用δ=14mm板制成,硝盐炉衬采用超轻质高强度0.6g/cm3微珠耐火砖,夹层置硅酸铝纤维,炉衬与炉壳间填充保温膨胀保温粉,整个结构为标准型节能炉衬,硝盐炉的发热元件采用较粗直径0Cr25Al5高温电阻丝绕成螺旋状按照均温布丝法,安置在炉衬的搁丝砖上,搁丝砖采用前部上翘20°防掉丝砖,电阻丝不易掉出。

第55/100页 首页 < ... 51 52 53 54 55 56 57 58 59 ... > 尾页
相关中文对照歌词
Heat Of The Night
The Heat Is On
Children In Heat
The Heat Is On
Turning Up The Heat
The Heat (Outro)
The Heat
Heat Of The Night
Heat Of The Moment
The Heat Goes On
推荐网络例句

This one mode pays close attention to network credence foundation of the businessman very much.

这一模式非常关注商人的网络信用基础。

Cell morphology of bacterial ghost of Pasteurella multocida was observed by scanning electron microscopy and inactivation ratio was estimated by CFU analysi.

扫描电镜观察多杀性巴氏杆菌细菌幽灵和菌落形成单位评价遗传灭活率。

There is no differences of cell proliferation vitality between labeled and unlabeled NSCs.

双标记神经干细胞的增殖、分化活力与未标记神经干细胞相比无改变。