查询词典 fluid statics
- 与 fluid statics 相关的网络例句 [注:此内容来源于网络,仅供参考]
-
Five novel torsion-mirror optical actuators including double-beam thickness differential structure with single torsional axis, double flexible folded-beam structure with single torsional axis, double-beam vertical torsion comb structure with single torsion axis, four-beam differential compound-micromirror structure with double torsional axis and the combined structure of the four basis forms above, are brought forward. All of these devices could be fabricated by the same silicon micromachining process we have developed. The deformation compensation design with local enhancement for the thin torsional beam which is the key structure of these devices is also put forward to improve the reliability. The three-dimension solid model and two-dimension reduced order model of the torsion-mirror optical actuator are established and then the numerical simulations for evaluating the device characteristics of the statics, dynamics, electrostatic field, mechanical and electrostatic coupling, fluid and solid coupling are carried out to optimize the structure design. Furthermore, three optical fibre clamping structures which could be integrated monolithicly are designed and analyzed to improve the optical coupling capability. 4. Three flexible process flows combined with bulk silicon micromachining and surface silicon micromachining are brought forward to fabricate these novel single-crystal silicon or polysilicon torsion-mirror optical actuators by using the same lithography masks for both SOI wafer and regular silicon wafer. A series of important process experiments are carried out to optimize the process parameters and the process flows. Some novel and typical process phenomena which occurred during the microfabrication are analyzed and then the corresponding solutions are put forward. 5. A MEMS dynamic testing system which exploit blur image synthetic technique, stroboscopic image matching technique, stroboscopic mirau microscopic interferometry technique and microscopic laser dopper vibrometer technique is set up to measure three-dimension and six-freedom micro motions of any MEMS devices with nanometer resolution.
在对硅微机械扭转镜光致动器的光机电特性系统地理论研究的基础上提出了硅微机械扭转镜光致动器的结构设计准则。3、提出了单轴双梁厚度差分结构、单轴双柔性折叠梁结构、单轴双梁垂直扭转梳齿结构、双轴四梁差动复合微镜结构以及以上四种基本结构组合后的衍生结构等五种工艺加工技术兼容的新型的硅微机械扭转镜光致动器,对器件关键结构薄厚度、高耐疲劳扭转梁进行了局部加强的变形补偿设计,建立了器件的三维实体模型以及两维降阶模型,对提出的新结构硅微机械扭转镜光致动器进行了系统的静力学、动力学、静电场、力电耦合和流体固体耦合的建模仿真与优化设计,同时设计并分析了三种可实现单芯片集成的弹性光纤定位夹紧结构。4、提出了组合体硅微加工技术与表面硅微加工技术、兼容同一套光刻版图、可分别基于SOI 晶片和普通Si 晶片、适应于制造提出的各种新结构单晶硅和多晶硅硅微机械扭转镜光致动器的三套柔性加工工艺流程,开展了一系列重要工艺步骤的单项工艺试验,对工艺流程与工艺参数进行了优化,针对加工过程中出现的具有普遍意义的典型工艺问题进行了讨论和分析,并提出了解决方法。5、创新性地将模糊图像合成技术、频闪图像匹配技术、频闪Mirau 显微干涉技术与显微激光多普勒测振技术有机结合,建立起了一套周期运动测量与瞬态运动测量相结合、单点运动测量与全视场运动测量相结合、满足不同MEMS 器件各种动态测试要求的集成的MEMS 三维六自由度微运动精密测量系统。
-
Note that fluid mechanics can be further split into fluid statics and fluid dynamics, and is itself a subdiscipline of continuum mechanics.
注意到流体力学可以被更进一步分成流体静力学与流体动力学,并且它是连体力学底下的分支。
-
The difference of fluid statics between different infiltration modes was studied. It was found that it was necessary to apply pressure to assure the transverse infiltration even if the C/Mg composite is a wettable composite system.
研究了不同浸渗方式的流体静力学差异,发现即使对于润湿的复合材料体系,外加压力也是保证横向浸渗顺利进行的必要条件。
- 推荐网络例句
-
They weren't aggressive, but I yelled and threw a rock in their direction to get them off the trail and away from me, just in case.
他们没有侵略性,但我大喊,并在他们的方向扔石头让他们过的线索,远离我,以防万一。
-
In slot 2 in your bag put wrapping paper, quantity does not matter in this case.
在你的书包里槽2把包装纸、数量无关紧要。
-
Store this product in a sealed, lightproof, dry and cool place.
密封,遮光,置阴凉干燥处。