英语人>网络例句>Ray 相关的网络例句
Ray相关的网络例句
与 Ray 相关的网络例句 [注:此内容来源于网络,仅供参考]

It reformed the coventional grazing incidence method of reflecting x ray, and made it possible to reflect x ray in normal incidence way. It moves x ray optics forward greatly.

它从根本上改变了传统的掠入射反射x光的方法,使正入射反射x光成为可能,并极大的促进了x光学的发展。

Numerical simulations show that the results are accordant with conservation of energy; electrical field or magnetic field of the ray refracted to the isotropic medium does not parallel to the electric field or the magnetic field of original incident ray; the direction of optical axis and the magnitude of incident angle have a great effect on the energy and the polarization direction of the refracted ray.

数值模拟表明,所得结果满足能量守恒;射入各向同性介质中光的电场与原入射光的电场不再平行;光轴的取向和入射角的大小对折射光的偏振方向和能量有重大影响。

The oxide films were investigated by means of scanning electron microcopy, energy dispersion X-ray microanalyser, X-ray diffraction and X-ray photoelectron spectroscopy.

用扫描电镜、能谱仪、X封线衍射、X射线光电子能谱时氧化膜进行了研究。

The company owns 36 γ-ray sources (26 Ir192γ-ray sources and 10 Se75γ-ray sources), 27 300kV radiographic machines, 84 250kV radiographic machines, 43 200kV radiographic machines, 25 ultrasonic equipments, 4 NITON portable alloy analyzers for Positive Material Identification, 18 mobile dark rooms, 8 pipe crawlers and 29 units/sets of physical and chemical inspection equipments.

公司有γ源36枚( Ir192源26枚, Se75源10枚),300KV 射线机27台,250KV 射线机84台,200KV 射线机43台,超声波探伤仪25台, NITON 光谱仪4台,活动暗室18个,管道爬行器8台,理化检验设备29台套。

Second: Comparetive study of ordinary X-ray film, CT and 3D-CT in the jaws fractures. Ordinary X-ray film, CT and 3D-CT was performed in 61 cases of jaws fractures. The diagnosis of these three imaging methods was compared with each other and with the operation findings. The result shows that the fractures in body and angle part of mandibal could be shown excellently by all these imaging methods. 3D- CT is the best method in showing the mandibular fractures. Ordinary X- ray film is poor, and the accuracy of CT and 3D-CT is similar in showing the macxillary fractures.

二。颌骨骨折的常规X线、CT和三维CT对比研究:通过对61例不同类型的上、下颌骨骨折常规X线、CT和三维CT显示情况的对比分析,同时与手术结果相对照,结果表明对下颌骨体部和角部的骨折三种影像学检查均显示准确;对下颌骨髁状突骨折的显示三维CT优于CT和常规X线;对上颌骨骨折的显示常规X线显示较差,CT和三维CT显示准确率相似。

And by applying the linear dispersion relation of wave, all the properties of wave refraction including wave rays, constant phase lines, phase function and crest lines etc., can be expressed in explicit functions. By introducing an orthogonal curvilinear coordinate along the wave ray and the constant phase line, and with an estimated scale factor, the refraction coefficients along any wave ray can then be determined. The present results are verified by ordinary wave ray theory and some previous numerical results.

就此特例情况在波浪的线性分散关係的应用下,前进波浪折射现象的整体特性,包括波向线、等位相线、位相函数与波峰线皆被导述出明確显然的函数表示;同时引入由沿著波向线与等位相线所构成的完全符合波浪折射几何通性的正交曲线座標,求出其尺度因子后,由能通量守衡原则定出沿著任一条波向线上的折射係数;並由之对往昔纯依两相邻的波向线间的几何类比所给定的折射係数给予导証之。

Results Metaphysis osteoporosis was observed on X-ray and CT in acute stage, the midsection of infarct of bone was isointensity on T1WI and iso/hyperintensity signal on T2WI, the edge of infarct of bone was ring-shaped hypointensity on T1WI and hyperintensity signal on T2WI. Small worm-eaten change and stippled calcification was observed on X-ray and CT in subacute stage, the infarct of bone was iso/hypointensity on T1WI and iso/hyperintensity signal on T2WI, the edge of infarct of bone was ring-shaped hypointensity on T1WI and hyperintensity signal on T2WI. Irregular and wriggle osteosclerosis was observed on X-ray and CT in chronic stage, was hypointensity on T1WI and T2WI.

结果 骨梗死急性期X线、CT表现为干骺端骨质疏松,MR T1WI骨梗死灶中央部分呈等至高信号,T2WI呈高信号,T1WI骨梗死灶边缘呈环形低信号,T2WI呈环形高信号;亚急性期X线、CT表现为小的虫噬样改变,伴有斑点状钙化,MR T1WI骨梗死灶呈等或低信号,T2WI呈等或稍高信号,T1WI骨梗死灶边缘呈环形低信号,T2WI呈环形高信号;慢性期X线、CT表现为不规则状、蜿蜒状骨质硬化,MR T1WI和T2WI均呈低信号。

This project is to analyze the distribution of the light in the high-power laser system, it bases on principles of ray optical, use the paraxial ray trace and real ray trace , proposes a new data structure and way to simulate the light in the optical system in the computer.

本课题就是以含衍射元件的大功率激光装置中由于多次残余反射形成的鬼像为研究对象,从光线光学的基本原理出发,应用近轴光线与空间光线追迹相结合的技术路线,提出一种新型的分析方法和数据结构,开发出用于含衍射元件的高功率激光系统杂散光分析的软件。

To solve this problem, according to the analysis of the quality factors of the X-ray, the measurement for X-ray tube voltage/current is presented based on Q-factor and its derived QL and QH-factor when X-ray tube energy bandwidth is defined.

针对传统的管电压/管电流测量方法虽然可以检测出X射线管电压/管电流误差值,但不能反映其质量特征的状况,在分析影响X射线质量高低的因素的基础上,引入了射线管能量带宽的含义,并由此提出了基于Q值及其派生QL值、QH值的射线管电压/管电流分析方法。

It is suggested by our test work on radon mapping of geology that there is a good coincidence between the data got from gamma-ray spectrometer and radon monitor and the U、Th、Ra、K data got from indoor gamma-ray spectrometer and radiochemistry method; the data of gamma-ray spectrometer and radon monitor are also comparative to the 1∶20 ten thousand geochemistry data of U、Th、 Ra (calculated by the equilibrium coefficient between U and Ra) and radon concentrations measured by solid state nuclear track detector .

在国内首次利用地质勘探费用进行氡地质填图方法试验,该试验方法结果表明,利用国产的现场能谱仪、测氡仪获得的数据与室内能谱仪、化学法测得的铀、钍、镭、钾结果一致;与已有的1∶20万区域地球化学数据铀、钍、镭(由铀、镭平衡系数计算得出)、钾和固体核径迹累积法测氡数据具有很好的可比性。

第24/100页 首页 < ... 20 21 22 23 24 25 26 27 28 ... > 尾页
相关中文对照歌词
Ray
Gamma Ray
Ray...
Yo El Ray
The Man With The X-Ray Eyes
Gamma Ray
Ray Gun
X-Ray
X-Ray Eyes
Ray Ray's Juke Joint
推荐网络例句

The split between the two groups can hardly be papered over.

这两个团体间的分歧难以掩饰。

This approach not only encourages a greater number of responses, but minimizes the likelihood of stale groupthink.

这种做法不仅鼓励了更多的反应,而且减少跟风的可能性。

The new PS20 solar power tower collected sunlight through mirrors known as "heliostats" to produce steam that is converted into electricity by a turbine in Sanlucar la Mayor, Spain, Wednesday.

聚光:照片上是建在西班牙桑路卡拉马尤城的一座新型PS20塔式太阳能电站。被称为&日光反射装置&的镜子将太阳光反射到主塔,然后用聚集的热量产生蒸汽进而通过涡轮机转化为电力