- 更多网络例句与判读误差相关的网络例句 [注:此内容来源于网络,仅供参考]
-
In order to reduce the error of a remote sensing area sentencing in two-stage survey of investigations, this article used the Bo'ai County state-owned tree farm partial remote sensing TM satellite picture and the correlation data establishes the visual solution to symbolize that, according to the solution which established translates the symbol to the place thing to carry on the remote sensing to interpret,cancelled in the room draws each place kind of boundary, extracted on the chart with the polyester membrane the area, may calculate according to the proportion interprets the area ,figured out interprets the area, simultaneously in order to enhance interprets the precision to obtain a more real reliable material, investigated 90 bottom classes in kindergarten's area from the location, and interpreted to these 90 bottom classes in kindergarten on the chart obtains the corresponding area,simultaneously established the linear model.
为了减少二类调查中遥感地类面积判读误差,本文利用博爱县国有林场部分遥感TM卫星图片和相关资料建立了目视解标志,根据所建立的解译标志对地物进行遥感判读,在室内勾绘出各地类边界,用聚酯膜求出图上面积,根据比例计算出判读面积,同时为了提高判读精度得出更加真实可靠的资料,从现地中调查了90个小班的面积,并对这90个小班在图上判读得出相应的面积,同时建立线性模型。
-
The paper describes basic working principles of SDH-5 type water-depth measurement instrument. Aiming at the time disagreement between water-depth data and position data,the big error in the reading of water-depth measurment data, low automation,large amount of work in homework data processing, etc.
本文描述了SDH-5型测深仪的基本工作原理,并针对国产SDH系列模拟式水深测量仪器存在水深数据与定位数据记录时间不一致、水深测量数据判读误差大、自动化程度低、内业数据处理工作量大等缺陷,介绍了作者应用单片机技术研制的SDH-5/CLZ-Ⅰ型水深数据采集、处理与串行发送装置。
-
In traditional methods which are full of error and lack of efficiency, the focal plane is interpreted.
传统的检焦方法是用人眼对焦面进行判读,这种方法误差大,效率低。
-
However, at least 1 outside observer urged caution in interpreting these findings."The reliability and validity of high-resolution computerized tomography in kidney failure has been questioned," Ell Friedman, MD, nephrologist and Distinguished Teaching Professor of Medicine at the State University of New York Downstate Medical Center in Brooklyn, told Medscape Nephrology . He cited a recent study by Barraclough et al ( Nephrol Dial Transplant . Published online before print May 1, 2008) showing significant imprecision in HRCT-derived validation of coronary calcification in kidney failure patients, depending on who reads the results.
然而,至少一位以上的外部观察者表示在阐释这些研究发现时必须特别小心,布鲁克林纽约州立大学Downstate医学中心的肾脏学家与卓越教学医学教授Ell Friedman医师向Medscape肾脏学表示,高解析度电脑断层扫描应用於肾脏衰竭上的信度与效度已经受到质疑;他引用最近一项由Barraclough等人(发表於Nephrol Dial Transplant,於2008年5月1日线上发表)的研究结果,显示HRCT延伸的肾脏衰竭病患冠状动脉钙化检验有相当程度的误差,取决於谁判读检验结果。
-
Presently, the reading work of the dial indicator in our country still adopts the manual method. This method is restricted by such subjective factors as observing angel and distance as well as fatigue strength and so on, which results in not only large error and low reliability but also low efficiency and great labor costs.
目前国内对这类仪表的判读工作主要是采用人工观测仪表表盘指针来读数的方法,这种方法受人的主观因素如人的观测角度、观测距离及疲劳强度等的影响,误差较大,可靠性不高,且工作效率低,劳动强度大。